The CW-106 CANswitch FD establishes a connection via CAN bus between an existing topology (main CAN bus) and the output channels (bi- and unidirectional CAN bus).
The output channels (CAN bus) are galvanically isolated from each other and from the power supply, up to 1 kV. The entire message traffic of the existing topology including error frames can be forwarded by the CW-106. This enables an extension of the topology without influencing the existing system.
The CW-106 CANswitch FD establishes a connection via CAN bus between an existing topology (main CAN bus) and the output channels (bi- and unidirectional CAN bus).
The output channels (CAN bus) are galvanically isolated from each other and from the power supply, up to 1 kV. The entire message traffic of the existing topology including error frames can be forwarded by the CW-106. This enables an extension of the topology without influencing the existing system.
Quantity | 6, galvanic isolation up to 1 kV |
Type | ISO 11898-2 (high-speed) CAN protocol versions 2.0 A and 2.0 B |
Data rate | up to 8 Mbit/s |
Terminination | Bidirectional: via DIP-Switch |
Connector | Main-CAN-Bus: 2 x D-Sub 15 pol. |
Supply volatage | 9 VDC to 36 VDC | |
current consumtion | 150 mA at 12 VDC | |
Connector | LEMO EPG.0B.305 |
Temperature | -20 °C to +70 °C |
Relative Humidity | 35 % to 85 %, non-condensing |
Housing | Robust aluminium housing |
Dimension (LxBxH) | 104 mm x 130 mm x 36,4 mm |
Weight | 350 g |
Features | Galvanic isolation up to 1 kV between CAN-Channel and Supply voltage Representation of the bus load via LED |
© 2024 CANWAY TECHNOLOGY GmbH