CAN-CONTROLLED POWER SUPPLY
The module CW-301 makes it possible to switch power relays by means of CAN messages and manual switches. As a consequence, it is possible, for example, to switch on the power supply to mobile measuring equipment by means of a specific CAN bus signal (e.g., KL15) or charge batteries installed in measurement technology to defined vehicle states.
The CW-301 is equipped with three switchable outputs and can be operated with a maximum switching current of 30 A. 10 A thermal circuit breakers protect the manual and CAN controlled circuits.
It is possible to configure a wide range of different settings via the CAN protocol, such as the baud rate, CAN message, sleep mode and follow-on time.
PERFORMANCE CHARACTERISTICS
- 3 voltage outputs 12 VDC or 24 VDC
- 10 A switching current per voltage output
- Protected by thermal circuit-breakers
- Manual or CAN controlled voltage outputs
- CAN message, CAN signal and switching conditions user selectable
- Low current consumption in sleep mode
- Adjustable follow-on time up to 1 hour
TECHNICAL DATA
Voltage Outputs
Number: | 3 |
Nominal voltage: | 12 VDC or 24 VDC |
Switching current: | 10 A per voltage output (protection though thermal circuit breaker) |
Switching power max. | 120 W per channel at 12 VDC |
Switching cycles: | ≥ 100.000 |
Response time / fall time: | ≤ 10 ms (at 20 °C) |
Connector: | Socket for 4mm connector (banana jack) |
CAN-INTERFACE
Number: | 1 |
Type: | ISO 11898-2 (highspeed) CAN-protocol version 2.0 A and 2.0 B, supports SAE J1939 (29-bit-identifier) |
Data rate: | 50, 100, 125, 250, 500, 800 and 1000 kBit/s configurable via CAN-bus |
Termination: | 120 Ohm, optional |
Connector: | D-Sub9-connector |
Power supply
Supply voltage: | 9 to 30 VDC |
Current consumption: | 30 mA at 12 VDC (unswitched) 510 mA at 12 VDC (switched on, without load current) |
Connector: | LEMO ECG.3B.302 |
Environmental conditions
Temperature range operation: | -20 °C to +70 °C |
Temperature range storage: | -20 °C to +85 °C |
Relative humidity: | 35 % to 85 % non-condensing |
Protection class: | IP40 |
General Information
Housing: | HF-Tubus |
Dimensions (LxWxH): | 71 mm x 131 mm x 171 mm |
Weight: | 1.100 g |
Download
Datasheet CW-301
Download (PDF)Back to the overview | CW-300 Series